Passive Protection equipments

Passive lightning air terminal unlike Active lightning one(ESE) does not have any reaction against lightning strike . Hence, it is called passive , inactive or simple .
Passive lightning rod , in fact , is what Benjamin Franklin invented in 1752 to avoid lightning damages and has also been used so far.
According to Standard, Lightning protection system consists of three parts: Air Termination, Down Conductor and Earth termination Earth Termination.
The only major difference between passive and active systems is the air terminal type . Air terminal in passive systems can be usually in the form of rods, hanging wires or mesh ( Faraday cage) .
International Standard IEC 62305-3 ( Part III ) as the main reference of the basic principles of passive protection systems ,describes the design, installation and maintenance of the system. In addition, the standards like BS6651, NFPA780 and DIN VDE 0185 are also used .

Passive Protection Volume

 

  • Franklin Simple Rod

Simple Franklin rod for using in external Lightning protection

- Made of AISI 316 Stainless Steel or Copper

- Complies with the requirements set forth in the standards: EN 62.305

- Can be made in any length required (20 - 200 Cm)

- see dimensions

 

  • Multiple Franklin rod

Multiple Franklin lightning rod with adapter part included, for using in external Lightning protection

- Adapter can be delivered for cable or tape down conductor connection

- Made of AISI 316 Stainless Steel or Copper

- Complies with the requirements set forth in the standards: EN 62.305

- Available in any length required (20 - 200 Cm)

- see dimensions

- see the picture

 

  • High Sensitivity Electromechanical Lightning Counter

This counter specifically has been designed for passive systems with multiple down conductor or for those active systems in which down conductor has interconnections with structure's metallic parts.

- Does not need external power supply

- Current Intensity Range: 100 A (8/20 µs) - 100 kA (10/350 µs), (EN 50.164-6:2009)

- Available for: Cable 50-95 mm², Rod Ø 8-12 mm. Tape 30x2mm (adapter kit)

- Application standards:

- NFC 17-102
- EN 50.164
- EN 62.305
- CTE

- Made by INGESCO Spain

- Download Technical Sheet

 

 

  • Test Joint in Box

Wall mounted grounding test joint, including a Cu/Zn alloy (brass) manual disconnection system and 160x118x75 mm PVC box, water resistant (IP 65).

Complies with the requirements set forth in the standards:

- UNE 21.186
- NFC 17.102
- EN 50.164/1
- EN 62.305

Specially made for 50 mm² cross section Cu cable down conductors.

Fittings also available for connection of 70 and 95 mm² cross section cables and for copper tape 30x2 mm down conductors.

Stainless steel hardware.

- Click to see inside pieces

- See the Dimensions

  • System Accessories and Connections

Franklin rods

Simple Rods

Simple rods in various lengths and diameters

Multiple rods in various lengths and diameters

Made of SS or Ni-Chrome clad Cu

saddles

Saddles suitable for simple rods

Saddle for horizontal roofs

Saddle for slopped roofs

Available for cable or tape conductor

Made of Brass

Adaptor, Mast, ...

Adapters and saddles

Brass made adapters for rods

wall mount saddle

Air terminal masts

Down conductor brackets

Wall mount Cable fastener

Tape fastener and clamp

Bonding clamp connectors

Conductor clamps

Mesh and T connection clamps

Cable to tape connectors

Cable to Cable Connectors

Cable lugs and connector clamps

Tin coated copper cable lugs

Cable to tube bonding connection

Wall mount tape fastener

 